Choose one or more compatible UDI Sets depending on the number of samples to be multiplexed and the Illumina instrument (using Forward Strand or Reverse Complement Workflow for dual-indexing) where the libraries will be sequenced. See Table 1 for details.

...

  • UDI Primer Plate Only (amplification reagents not included)

  • UDI Add-on Kits (primer plate + amplification reagents)

  • UDI Kit Bundles (library prep kit + primer plate + amplification reagents)

NOTE: The UDI Add-on Kits can be used in combination with Base Kits that contain no indices or that contain 6 nt i7 indices. When using the Base Kits indicated below, one of the UDI Primer Plates or Add-on Kits will be needed in addition. However, if UDIs should be included in libraries, we recommend purchasing the Kit Bundles for ease of use.

Table 2: Lexogen UDI 12 nt Unique Dual Indexing product compatibility with Library Prep Kits.

 

Library Prep Type

 

Base Kit(s)

with 6 nt indices or no indices included.

UDI Products

UDI Primer Plate Only

UDI Add-on Kits

(Primer Plate, Buffer, and Enzyme)

UDI Kit Bundles

(Library Prep Kit + UDI Primer Plate, Buffer, and Enzyme)

QuantSeq-Pool1

Cat. No. 139

OPTIONALLY one of:

Cat. No. 101: Set A1

Cat. No. 102: Set A2

Cat. No. 103: Set A3

Cat. No. 104: Set A4

Cat. No. 156: Set A1 - A4

Cat. No. 105: Set B1

LUTHOR2

Cat. No. 143

AND one of:

Cat. No. 101: Set A1

Cat. No. 102: Set A2

Cat. No. 103: Set A3

Cat. No. 104: Set A4

Cat. No. 156: Set A1 – A4

Cat. No. 105: Set B1

QuantSeq FWD3

Cat. No. 015

 

AND one of:

Cat. No.

107

198: Set A1

Cat. No.

108

199: Set A2

Cat. No.

109

200: Set A3

Cat. No.

110

201: Set A4

Cat. No.

120

203: Set A1 - A4

Cat. No.

111

202: Set B1

OR one of the following UDI Kit Bundles:

Cat. No.

113 – 115, 129 – 131

191 - 196

QuantSeq-REV3

 

Cat. No. 016

AND one of:

Cat. No.

107

198: Set A1

Cat. No.

108

199: Set A2

Cat. No.

109

200: Set A3

Cat. No.

110

201: Set A4

Cat. No.

120

203: Set A1

- A4

Cat. No.

111

202: Set B1

QuantSeq-Flex3

Cat. No. 166 AND/OR

Cat. No. 028

 

AND one of the following QuantSeq FWD UDI Kit Bundles

Cat. No.

113 – 115, 129 – 131

CORALL V2

NA

Cat. No. 171 – 176 - stand alone kits

Cat. No. 177 - 182 - with Poly(A) RNA Enrichment

Cat. No. 183 - 186 - with RiboCop rRNA Depletion

CORALL V1

191 - 196

CORALL

Cat. No. 095 (stand alone kit) OR

Cat. No 144 - 146 (RiboCop bundles)

 

 AND one of:

Cat. No.

107

198: Set A1

Cat. No.

108

199: Set A2

Cat. No.

109

200: Set A3

Cat. No.

110

201: Set A4

Cat. No.

120

203: Set A1 - A4

Cat. No.

111

202: Set B1

OR one of the following UDI Kit Bundles:

Cat. No.

117 - 119, 132 - 134

171 – 176 - stand alone kits

Cat. No.

158

177 -

163

182 - with Poly(A) RNA Enrichment

Cat. No. 183 - 186 - with RiboCop rRNA Depletion

Other Vendor Libraries4

NA

 

OPTIONALLY one of:

Cat. No.

107

198: Set A1

Cat. No.

108

199: Set A2

Cat. No.

109

200: Set A3

Cat. No.

110

201: Set A4

Cat. No.

120

203: Set A1 - A4

Cat. No.

111

202: Set B1

 