What are the input RNA requirements?

Lexogen Online FAQs

What are the input RNA requirements?


The Small RNA-Seq kit can be used for inputs from:

  • 100 ng – 1,000 ng of cellular total RNA or whole blood RNA;

  • 50 pg – 1,000 ng of enriched small RNA and low RNA content samples such as plasma, serum, urine, exosomal RNA, etc.

In general, we recommend using >100 ng of total RNA input from cells or tissues.

For 1 - 100 ng input amounts, we recommend using 0.5x dilution of 3' Adapter (A3), 5' Adapter (A5) and Reverse Transcription Primer (RTP) and 50 µl of EtOH in Step 5 of the library prep protocol.

Input amounts lower than 1 ng require further adapter dilutions and protocol adjustments. For more information, see this FAQ and Appendix B of the Small RNA-Seq User Guide.


 

Related content

Are there recommendations for low RNA input?
Are there recommendations for low RNA input?
More like this
I can only extract a limited amount of RNA from my starting material. How much RNA should I send for library preparation?
I can only extract a limited amount of RNA from my starting material. How much RNA should I send for library preparation?
More like this
What are the input RNA requirements for QuantSeq REV?
What are the input RNA requirements for QuantSeq REV?
More like this
What are the input RNA requirements for QuantSeq FWD?
What are the input RNA requirements for QuantSeq FWD?
More like this
Do I need to purchase additional kits, e.g., for purification?
Do I need to purchase additional kits, e.g., for purification?
More like this
What are the RNA input requirements for LUTHOR HD 3’ mRNA-Seq?
What are the RNA input requirements for LUTHOR HD 3’ mRNA-Seq?
More like this

Have feedback for us or need more information? Send us a request or write to us at support@lexogen.com.