What input amounts should I use?

Lexogen Online FAQs

What input amounts should I use?

FFPE tissue sample input should be 100-800 mm2 in surface or 1-15 mg in weight, and up to 10 µm in thickness. For higher input amounts, we strongly recommend performing a pilot experiment first to evaluate RNA extraction efficiency. If you have questions, please contact support@lexogen.com.

Below are general recommendations for maximum input, depending on the thickness and surface area of the FFPE slices:

Slice thickness

Maximum input

5 µm

1 slice with 1,600 mm2

2 slices with 800 mm2

3 slices with 530 mm2

4 slices with 400 mm2

10 µm

1 slice with 800 mm2

2 slices with 400 mm2

3 slices with 260 mm2

20 µm

1 slice with 400 mm2

2 slices with 200 mm2

3 slices with 130 mm2

4 slices with 100 mm2

For lower inputs, please refer to the following FAQ: How can I increase my final yield?

 

Related content

What are the key considerations when using this kit?
What are the key considerations when using this kit?
More like this
Do you have any specific recommendations for FFPE SPLIT RNA columns preparation?
Do you have any specific recommendations for FFPE SPLIT RNA columns preparation?
More like this
What are the Plate Adapters and when should I use them?
What are the Plate Adapters and when should I use them?
Read with this
What are the input requirements for QuantSeq FFPE?
What are the input requirements for QuantSeq FFPE?
More like this
What is the expected yield? Why is my yield low?
What is the expected yield? Why is my yield low?
Read with this
What are the input RNA requirements?
What are the input RNA requirements?
More like this

Have feedback for us or need more information? Send us a request or write to us at support@lexogen.com.